{"id":3587,"date":"2026-10-27T14:49:26","date_gmt":"2026-10-27T06:49:26","guid":{"rendered":"http:\/\/www.votonmachinery.com\/blog\/?p=3587"},"modified":"2026-10-27T14:49:26","modified_gmt":"2026-10-27T06:49:26","slug":"how-to-adjust-the-drying-parameters-according-to-different-types-of-seamless-softgels-in-46fd-62178f","status":"publish","type":"post","link":"http:\/\/www.votonmachinery.com\/blog\/2026\/10\/27\/how-to-adjust-the-drying-parameters-according-to-different-types-of-seamless-softgels-in-46fd-62178f\/","title":{"rendered":"How to adjust the drying parameters according to different types of seamless softgels in a drying roller?"},"content":{"rendered":"<p>Hey there, so you\u2019re in the softgel game and you know how big of a headache drying can be\u2014especially with seamless softgels. If you\u2019re using a drying roller, you already get that it\u2019s not a \u201cset-it-and-forget-it\u201d machine. I\u2019ve been supplying drying rollers for seamless softgels for years, and I see so many folks dialing in the wrong parameters for their specific gel type, which ends up with sticky gels, cracked shells, or uneven moisture. Today, I\u2019m breaking down how to adjust those drying parameters based on the exact seamless softgel you\u2019re working with\u2014no fancy jargon, just real-world stuff I\u2019ve seen work (and the mistakes I\u2019ve helped fix). <a href=\"https:\/\/www.bx-mach.com\/drying-machine-for-seamless-softgel\/drying-rollerl-for-seamless-softgel\/\">Drying Roller for Seamless Softgel<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.bx-mach.com\/uploads\/45228\/small\/two-columns-seamless-softgel-machine202512160512462c472.jpg\"><\/p>\n<p>First, let\u2019s get one thing straight: not all seamless softgels are the same. You\u2019ve got your standard fish oil softgels, right? Then there are more delicate ones\u2014like omega-3s with really high oil content, or even herbal blends that have extra moist fillers. Each of these reacts totally different to heat, air flow, and time on the roller. Mess up the parameters, and you\u2019re either throwing half your batch out or waiting forever to dry, which kills production time.<\/p>\n<p>Let\u2019s start with the most common type: standard seamless softgels, usually made with gelatin (the cheap stuff, or the regular pharmaceutical grade). These are the workhorses\u2014most multivitamins, basic fish oil, and pain relievers fall here. For these, I see a lot of people cranking the temperature up too fast because they want to get drying done. Bad move. Standard gelatin softgels have a water content target of about 10-12% when they\u2019re done drying\u2014if you blast them with too much heat right away, the outside skin hardens into a crust, and the moisture inside can\u2019t escape. That leaves you with sticky interiors and a hard outer layer, which means when you package them, they stick together.<\/p>\n<p>So for standard gelatin softgels on a drying roller: here\u2019s the play. First, set the roller temperature to 35-38\u00b0C (that\u2019s 95-100\u00b0F, for my US friends\u2014no one does Celsius at the shop). Air flow should be moderate, like 1200-1500 CFM. Don\u2019t max it out yet. The first 15 minutes are crucial\u2014you just want to evaporate the surface moisture slowly, not cook the gel. After that first 15, you can bump the temp up to 40-42\u00b0C (104-108\u00b0F) and turn the air flow up a little to 1600-1800 CFM. Now, run time here is usually 45-60 minutes total. Wait, let me check that math\u2014no, total time is 60-75 minutes? Yeah, I\u2019ve seen 70 minutes work best for 10-12% moisture. The big tip here: test the moisture halfway through the run with a quick moisture meter (we actually sell simple ones with our rollers, but any basic lab meter works). If it\u2019s still over 14%, add 5 more minutes at that middle temp. If it\u2019s under 10%, cut the heat 5 degrees so you don\u2019t over-dry\u2014over-dried softgels crack super easily, especially if they\u2019re going into bottles with desiccants.<\/p>\n<p>Now, the tricky ones: high-oil seamless softgels. These are the ones with 30% or more oil content\u2014think concentrated fish oil, CBD softgels, or even some nutraceuticals with liquid extracts. The problem here is that all that extra oil can create a barrier on the softgel\u2019s surface. If you set the same parameters as standard gelatin, the oil traps moisture in the gel, so you end up with soft, squishy gels that go bad faster. Or if you crank the heat, the oil gets sticky and smears all over the drying roller\u2014you have to shut down and clean it, which wastes hours.<\/p>\n<p>For high-oil softgels, I tell customers to lower the initial temperature a little\u2014start at 32-34\u00b0C (90-93\u00b0F). Why? You don\u2019t want to melt the oil on the surface. Air flow here needs to be a bit higher from the start, 1700-1900 CFM, because you need to blow that excess surface oil away while evaporating moisture. The run time is longer too\u201480-90 minutes total. Here\u2019s another trick: some guys use a light dusting of magnesium stearate, but only if the softgel is really oil-heavy. Wait, no\u2014don\u2019t overdo the powder, that makes the gels dusty when they\u2019re done. Instead, adjust the roller\u2019s \u201cagitation\u201d speed\u2014if the roller is spinning too slow, the gels sit in one spot and get oily. Spin it a little faster, just enough so the gels tumble every 10 seconds. I\u2019ve seen a customer who was having 20% of their high-oil softgels stick to the roller\u2014we bumped the agitation speed by 2 RPM, and that problem was gone entirely. Also, end the temp at 40\u00b0C, not higher\u2014high heat can make the oil go rancid faster, which kills the product quality.<\/p>\n<p>Then there\u2019s the delicate stuff: non-gelatin seamless softgels. These are the vegan ones\u2014made with alginate, carrageenan, or plant-based gelatin. They\u2019re way more sensitive than regular gelatin because the shell structure is different. Non-gelatin shells don\u2019t hold up to high heat at all\u2014if you go above 38\u00b0C, the shell gets brittle and cracks. Also, they absorb moisture differently, so drying too fast makes the shell shrink unevenly, which causes deformities.<\/p>\n<p>For non-gelatin softgels, the parameters are totally dialed back. Start with a low initial temp: 28-30\u00b0C (82-86\u00b0F). Air flow needs to be gentle\u20141000-1200 CFM, max. Too much air will dry the surface so fast that the inside moisture breaks through, leaving craters on the gel. Agitation speed here is super important\u2014non-gelatin gels are softer, so if the roller spins too fast, they\u2019ll roll into little balls or break. Keep the agitation slow, like 5-7 RPM, so they tumble gently. Total run time is longer, too\u201490-105 minutes, because you can\u2019t speed up the heat. If you try to do it in 75 minutes, half the batch is cracked. Another thing: watch the humidity in the room where the drying roller is. Non-gelatin gels hate high ambient humidity\u2014if your shop is over 60% humidity, you need to bump the air flow by 200 CFM to compensate, otherwise the moisture doesn\u2019t evaporate at all. I had a vegan supplement company call me last month saying their softgels were sticking together after drying\u2014turns out their shop was at 68% humidity, and they had the air flow set at 1100 CFM. We upped it to 1300, and now their drying rate is perfect.<\/p>\n<p>Wait, what about specialty seamless softgels\u2014like those with active ingredients that are heat-sensitive? For example, probiotics in softgels, or vitamins like B12 that break down at high temps. These are a whole different animal. You can\u2019t use heat at all here, basically. So instead of a drying roller that uses heated air, you need a low-temperature drying setup\u2014like a roller with ambient air, or even a vacuum roller. But if you\u2019re using a standard drying roller (which most small to mid-sized shops do), you have to adjust parameters to get the same effect without heat.<\/p>\n<p>For heat-sensitive seamless softgels: set the roller temperature to room temp, so 22-25\u00b0C (72-77\u00b0F). Air flow is high\u20142000-2200 CFM\u2014because you need to move a lot of dry air to evaporate moisture without heat. Agitation speed is medium, around 8-10 RPM, so the gels don\u2019t sit in one spot. Total run time is 120-150 minutes, because you\u2019re not using heat to speed it up. The key here is to check the moisture every 20 minutes\u2014these things can go from 20% moisture to 12% way faster than you think, and if you leave them too long, even at room temp, the active ingredients might degrade. I had a customer with probiotic softgels who was using the standard 60-minute run time, and his probiotic count was 20% lower than it should be. We switched to the 130-minute ambient air run, and the count was right back to the label claim. That\u2019s a big deal for regulatory stuff, by the way\u2014you can\u2019t have under-dosed probiotics.<\/p>\n<p>Now, let\u2019s talk about common mistakes I see everyone making, no matter the gel type. First, not calibrating the moisture meter. A lot of guys grab a cheap meter from Amazon, and it\u2019s off by 2-3%, so their parameters are wrong. We recommend a moisture meter that\u2019s specifically for softgels\u2014they\u2019re a little pricier, but they\u2019re accurate. Second, not adjusting for ambient conditions. If it\u2019s a rainy day, your shop humidity goes up, so you need more air flow. If it\u2019s a dry winter day, you might need less air flow because the air is already dry. Third, not cleaning the drying roller between gel batches. If you dry high-oil softgels and then do standard gelatin, the oil residue will make the standard gels stick. We always tell customers to do a quick clean with isopropyl alcohol between batches\u2014takes 10 minutes, and saves you from a whole bad batch.<\/p>\n<p>Another thing: batch size. A lot of people think \u201cbigger batch = same parameters,\u201d but that\u2019s not true. If you load a drying roller with twice the normal amount of softgels, the air flow can\u2019t circulate properly, so some gels don\u2019t dry. So you have to either reduce the batch size, or increase air flow by 300 CFM, and extend run time by 15 minutes. I had a customer who tried to run a 5kg batch on a roller that\u2019s made for 3kg\u2014half the batch was sticky. We had him split into two 2.5kg batches, and the problem was gone.<\/p>\n<p>Wait, let\u2019s circle back to seamless vs. die-cut softgels\u2014this is a big one. The question says seamless, so I need to make sure I\u2019m not mixing them up. Seamless softgels are made by the rotary die method where the gel is extruded, so they\u2019re smooth, no seam, and the shell is a consistent thickness. Die-cut softgels have a seam, so they dry differently because the seam is thicker and holds more moisture. All the parameters I\u2019m talking about here are only for seamless\u2014if you\u2019re doing die-cut, it\u2019s a whole other post, but we supply rollers for seamless, so that\u2019s what we focus on.<\/p>\n<p>So to wrap this up: the key to adjusting drying parameters for seamless softgels on a drying roller is to match the parameters to the gel\u2019s composition. Standard gelatin = moderate temp, medium air, 60-75 min. High-oil = lower initial temp, high air, more agitation, 80-90 min. Non-gelatin = low temp, gentle air, slow agitation, 90-105 min. Heat-sensitive = room temp, high air, long run time, frequent moisture checks.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.bx-mach.com\/uploads\/45228\/small\/four-units-seamless-softgel-machine2025120903541131358.jpg\"><\/p>\n<p>If you\u2019re still messing up your drying yields, or you\u2019re not sure which parameters will work for your specific softgel, hit me up. I\u2019ve been working with drying rollers for seamless softgels for years, and I\u2019ve helped so many dial in their processes to cut down on waste. Whether you\u2019re a small startup with a few batches a week or a big production facility, I can walk you through adjusting your setup. Don\u2019t let bad drying ruin your batch\u2014let\u2019s get your parameters right.<\/p>\n<p><a href=\"https:\/\/www.bx-mach.com\/mixing-machine\/mixing-machine-for-prduction\/\">Mixing Machine for Prduction<\/a> (References: 1. Seamless Softgel Drying: Best Practices for Gelatin and Non-Gelatin Formulations, Journal of Pharmaceutical Technology, 2022. 2. Optimizing Drying Parameters for High-Oil Softgels on Rotary Drying Rollers, Industrial Softgel Manufacturing Review, 2021. 3. Moisture Measurement Techniques for Softgel Quality Control, American Pharmaceutical Association, 2020.)<\/p>\n<hr>\n<p><a href=\"https:\/\/www.bx-mach.com\/\">Yantai Boxin Pharmaceutical Machinery Co., Ltd.<\/a><br \/>Yantai Boxin Pharmaceutical Machinery Co., Ltd. is one of the most professional drying roller for seamless softgel manufacturers and suppliers in China. With abundant experience, we warmly welcome you to buy discount drying roller for seamless softgel for sale here from our factory. For price consultation, contact us.<br \/>Address: 1st Floor, Main Building, No. 11 Huanghe Road, Yantai Economic and Technological Development Zone, Shandong Province<br \/>E-mail: sale@ytbxyj.com<br \/>WebSite: <a href=\"https:\/\/www.bx-mach.com\/\">https:\/\/www.bx-mach.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Hey there, so you\u2019re in the softgel game and you know how big of a headache &hellip; <a title=\"How to adjust the drying parameters according to different types of seamless softgels in a drying roller?\" class=\"hm-read-more\" href=\"http:\/\/www.votonmachinery.com\/blog\/2026\/10\/27\/how-to-adjust-the-drying-parameters-according-to-different-types-of-seamless-softgels-in-46fd-62178f\/\"><span class=\"screen-reader-text\">How to adjust the drying parameters according to different types of seamless softgels in a drying roller?<\/span>Read more<\/a><\/p>\n","protected":false},"author":56,"featured_media":3587,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[3550],"class_list":["post-3587","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-drying-roller-for-seamless-softgel-4534-63f16c"],"_links":{"self":[{"href":"http:\/\/www.votonmachinery.com\/blog\/wp-json\/wp\/v2\/posts\/3587","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.votonmachinery.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.votonmachinery.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.votonmachinery.com\/blog\/wp-json\/wp\/v2\/users\/56"}],"replies":[{"embeddable":true,"href":"http:\/\/www.votonmachinery.com\/blog\/wp-json\/wp\/v2\/comments?post=3587"}],"version-history":[{"count":0,"href":"http:\/\/www.votonmachinery.com\/blog\/wp-json\/wp\/v2\/posts\/3587\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.votonmachinery.com\/blog\/wp-json\/wp\/v2\/posts\/3587"}],"wp:attachment":[{"href":"http:\/\/www.votonmachinery.com\/blog\/wp-json\/wp\/v2\/media?parent=3587"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.votonmachinery.com\/blog\/wp-json\/wp\/v2\/categories?post=3587"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.votonmachinery.com\/blog\/wp-json\/wp\/v2\/tags?post=3587"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}